Solid Sawn Hangers
Fire Wall Hangers
FWH
Reference Series: DGHF
2015, 2018 & 2021 IBC/IRC Code Compliant
The FWH Fire Wall Hanger is designed for attaching truss, I-joist, solid sawn lumber, or engineered wood floor framing members to double wall top plates or minimum 2-ply 2x solid sawn header fire rated wood frame walls. The advanced design allows the installation of the FWH before the 5/8" gypsum wallboard (drywall) is attached and permits the building project to be completely framed-up, and weather-tight before the gypsum wallboard sheathing work starts.
2 Hour Fire Rating: FWH hangers are tested per ASTM E814 standards. When installed on one side of a maximum 2 hour fire-rated wall assembly, the penetration of the MiTek FWH Fire Wall Hanger through the gypsum wallboard will not reduce the fire resistive rating of the 2 hour fire resistive assembly.
Patents: U.S. No. 11,649,626
The FWH Fire Wall Hanger is designed for attaching truss, I-joist, solid sawn lumber, or engineered wood floor framing members to double wall top plates or minimum 2-ply 2x solid sawn header fire rated wood frame walls. The advanced design allows the installation of the FWH before the 5/8" gypsum wallboard (drywall) is attached and permits the building project to be completely framed-up, and weather-tight before the gypsum wallboard sheathing work starts.
2 Hour Fire Rating: FWH hangers are tested per ASTM E814 standards. When installed on one side of a maximum 2 hour fire-rated wall assembly, the penetration of the MiTek FWH Fire Wall Hanger through the gypsum wallboard will not reduce the fire resistive rating of the 2 hour fire resistive assembly.
Patents: U.S. No. 11,649,626
Materials: 14 gauge
Finish: G90 galvanizing
Code Reports:
View Code Report Table
Resources
MiTek Product CatalogInstallation
- Install the face of hanger flanges tight to stud wall framing.
- For wall framing, hangers do NOT need to be installed at stud locations for full design values.
- The end of the truss/joist should measure 1-5/8″ from the face of the supporting wall. See Figure 1.
- The truss/joist should bear fully on the FWH seat with a gap no greater than 1/8” between the end of the supported member and the hanger. See Figure 1.
- Gypsum Wallboard Installation – Use the FWH-T template to slot cut the gypsum wallboard. See FWH-T Template Sequence image. Slide the gypsum wallboard into position and fasten to the framing members meeting minimum requirements specified by code.
Need Help or Have a Question? Contact Customer Service or Call 800-328-5934
Videos
FWH Firewall Hanger Installation Instructions
FWH Fire Wall Hanger
Load Table
Solid Sawn Allowable Load Table
2-Ply, 2x Wall Top Plate Allowable Load Table
2-Ply 2x Wall Top Plate with Stud Below Allowable Load Table
Product / Geometry Table
Option Details:
Nailer Options Table
View / Download the above load table as a PDFSpecialty Options Table
View / Download the above load table as a PDFWelded Top Flange Installation
View / Download the above load table as a PDFCode Report Table
FWH-T
3-View Product Drawings
MiTek Stock # | Download or View Files | |||
---|---|---|---|---|
FWH17118 | DWG | DXF | View Image | |
FWH1714 | DWG | DXF | View Image | |
FWH1716 | DWG | DXF | View Image | |
FWH1795 | DWG | DXF | View Image | |
FWH20118 | DWG | DXF | View Image | |
FWH2014 | DWG | DXF | View Image | |
FWH2016 | DWG | DXF | View Image | |
FWH2095 | DWG | DXF | View Image | |
FWH210 | DWG | DXF | View Image | |
FWH212 | DWG | DXF | View Image | |
FWH23118 | DWG | DXF | View Image | |
FWH2314 | DWG | DXF | View Image | |
FWH2316 | DWG | DXF | View Image | |
FWH2318 | DWG | DXF | View Image | |
FWH2320 | DWG | DXF | View Image | |
FWH2395 | DWG | DXF | View Image | |
FWH25118 | DWG | DXF | View Image | |
FWH2514 | DWG | DXF | View Image | |
FWH2516 | DWG | DXF | View Image | |
FWH2518 | DWG | DXF | View Image | |
FWH2520 | DWG | DXF | View Image | |
FWH2595 | DWG | DXF | View Image | |
FWH28 | DWG | DXF | View Image | |
FWH35118 | DWG | DXF | View Image | |
FWH3514 | DWG | DXF | View Image | |
FWH3516 | DWG | DXF | View Image | |
FWH3518 | DWG | DXF | View Image | |
FWH3520 | DWG | DXF | View Image | |
FWH3522 | DWG | DXF | View Image | |
FWH3524 | DWG | DXF | View Image | |
FWH3595 | DWG | DXF | View Image |
Non-Structural: Product is not load rated and does not require code evaluation.